Injection Volume Is a Better Predictor of Stiffness Restoration Than Injection Force in an In Vitro Study of Nucleus Augmentation of the Intervertebral Disc
- DOI
- 10.1002/jsp2.70081
- Published
- 2025-06
- Container
- JOR SPINE
- Publisher
- Wiley
- Open access
- unknown
Credibility signals
uncertain Score 64/100 under policy 1.0.0. This is a metadata assessment, not a judgment of the paper's conclusions.
Show all credibility signals
- supportingDOI registered: A matching record was returned by Crossref.
- supportingDOI resolves: A matching record was returned by Crossref.
- not scoredDirectory of Open Access Journals: No matching DOAJ record was present in this response. No allow-list match; this is not evidence of low credibility.
- not scoredMEDLINE indexed: Not checked or no result supplied; no credibility inference made.
- not scoredOpenAlex core source: Not checked or no result supplied; no credibility inference made.
- not scoredKnown publisher allow-list: Not checked or no result supplied; no credibility inference made.
- not scoredROR affiliation: Not checked or no result supplied; no credibility inference made.
- not scoredRetraction Watch retraction: No retraction notice matched this DOI in the deployed snapshot. No matching event found; coverage may be incomplete.
- not scoredRetraction Watch expression of concern: No expression of concern notice matched this DOI in the deployed snapshot. No matching event found; coverage may be incomplete.
- not scoredRetraction Watch correction: No correction notice matched this DOI in the deployed snapshot. No matching event found; coverage may be incomplete.
- not scoredRetraction Watch reinstatement: No reinstatement notice matched this DOI in the deployed snapshot. No matching event found; coverage may be incomplete.
- not scoredOpen access status: Not checked or no result supplied; no credibility inference made.
- not scoredPublication license: Not checked or no result supplied; no credibility inference made.
- not scoredPublication version: A publication version was supplied but is not scored.
- supportingMetadata completeness: All 6 scored descriptive metadata groups are present.
Cite this work
BibTeX
@article{allodium:10.1002/jsp2.70081,
title = {Injection Volume Is a Better Predictor of Stiffness Restoration Than Injection Force in an In Vitro Study of Nucleus Augmentation of the Intervertebral Disc},
author = {J. P. Warren and A. R. Dixon and M. P. Culbert and A. Khan and M. Mengoni and R. K. Wilcox},
year = {2025},
journal = {JOR SPINE},
doi = {10.1002/jsp2.70081},
url = {https://doi.org/10.1002/jsp2.70081}
}RIS
TY - JOUR TI - Injection Volume Is a Better Predictor of Stiffness Restoration Than Injection Force in an In Vitro Study of Nucleus Augmentation of the Intervertebral Disc AU - J. P. Warren AU - A. R. Dixon AU - M. P. Culbert AU - A. Khan AU - M. Mengoni AU - R. K. Wilcox PY - 2025 JO - JOR SPINE DO - 10.1002/jsp2.70081 UR - https://doi.org/10.1002/jsp2.70081 ER -
APA
Warren, J. P., Dixon, A. R., Culbert, M. P., Khan, A., Mengoni, M., & Wilcox, R. K. (2025). Injection Volume Is a Better Predictor of Stiffness Restoration Than Injection Force in an In Vitro Study of Nucleus Augmentation of the Intervertebral Disc. JOR SPINE. https://doi.org/10.1002/jsp2.70081
Source records
- crossref · retrieved 2026-09-24T20:42:33.585Z