Comparative Efficacy of Flow Diverter Devices in the Treatment of Carotid Sidewall Intracranial Aneurysms: a Retrospective, Multicenter Study.

Dmytriw AA, Salim HA, Musmar B, Cancelliere NM, Griessenauer CJ, Regenhardt RW, Jones J, Tutino V, Hasan Z, Limbucci N, Lay SV, Spears J, Rabinov JD, Harrigan MR, Siddiqui AH, Levy EI, Stapleton CJ, Renieri L, Cognard C, Shaikh H, Kühn AL, Möhlenbruch MA, Tjoumakaris SI, Jabbour P, Taussky P, Settecase F, Heran MKS, Nguyen A, Volders D, Harker P, Devia DA, Puri AS, Psychogios M, Puentes JC, Leone G, Buono G, Tarantino M, Muto M, Briganti F, Dalal S, Gontu V, Alcedo Guardia RE, Vicenty-Padilla JC, Brouwer P, Schmidt MH, Schirmer C, Pickett GE, Andersson T, Söderman M, Marotta TR, Cuellar-Saenz H, Thomas AJ, Patel AB, Mendes Pereira V, Adeeb N, Flow diversion Multinational Observational cohort Device comparsion (FlowMOD) Investigators

Open source

DOI
10.1007/s00062-024-01435-x
Published
2024 Dec
Container
Clinical neuroradiology
Publisher
Not recorded
Open access
unknown

Credibility signals

limited evidence Score 43/100 under policy 1.0.0. This is a metadata assessment, not a judgment of the paper's conclusions.

Show all credibility signals

Cite this work

BibTeX

@article{allodium:10.1007/s00062-024-01435-x,
  title = {Comparative Efficacy of Flow Diverter Devices in the Treatment of Carotid Sidewall Intracranial Aneurysms: a Retrospective, Multicenter Study.},
  author = {Dmytriw AA and Salim HA and Musmar B and Cancelliere NM and Griessenauer CJ and Regenhardt RW and Jones J and Tutino V and Hasan Z and Limbucci N and Lay SV and Spears J and Rabinov JD and Harrigan MR and Siddiqui AH and Levy EI and Stapleton CJ and Renieri L and Cognard C and Shaikh H and Kühn AL and Möhlenbruch MA and Tjoumakaris SI and Jabbour P and Taussky P and Settecase F and Heran MKS and Nguyen A and Volders D and Harker P and Devia DA and Puri AS and Psychogios M and Puentes JC and Leone G and Buono G and Tarantino M and Muto M and Briganti F and Dalal S and Gontu V and Alcedo Guardia RE and Vicenty-Padilla JC and Brouwer P and Schmidt MH and Schirmer C and Pickett GE and Andersson T and Söderman M and Marotta TR and Cuellar-Saenz H and Thomas AJ and Patel AB and Mendes Pereira V and Adeeb N and Flow diversion Multinational Observational cohort Device comparsion (FlowMOD) Investigators},
  year = {2024},
  journal = {Clinical neuroradiology},
  doi = {10.1007/s00062-024-01435-x},
  url = {https://doi.org/10.1007/s00062-024-01435-x}
}

RIS

TY  - JOUR
TI  - Comparative Efficacy of Flow Diverter Devices in the Treatment of Carotid Sidewall Intracranial Aneurysms: a Retrospective, Multicenter Study.
AU  - Dmytriw AA
AU  - Salim HA
AU  - Musmar B
AU  - Cancelliere NM
AU  - Griessenauer CJ
AU  - Regenhardt RW
AU  - Jones J
AU  - Tutino V
AU  - Hasan Z
AU  - Limbucci N
AU  - Lay SV
AU  - Spears J
AU  - Rabinov JD
AU  - Harrigan MR
AU  - Siddiqui AH
AU  - Levy EI
AU  - Stapleton CJ
AU  - Renieri L
AU  - Cognard C
AU  - Shaikh H
AU  - Kühn AL
AU  - Möhlenbruch MA
AU  - Tjoumakaris SI
AU  - Jabbour P
AU  - Taussky P
AU  - Settecase F
AU  - Heran MKS
AU  - Nguyen A
AU  - Volders D
AU  - Harker P
AU  - Devia DA
AU  - Puri AS
AU  - Psychogios M
AU  - Puentes JC
AU  - Leone G
AU  - Buono G
AU  - Tarantino M
AU  - Muto M
AU  - Briganti F
AU  - Dalal S
AU  - Gontu V
AU  - Alcedo Guardia RE
AU  - Vicenty-Padilla JC
AU  - Brouwer P
AU  - Schmidt MH
AU  - Schirmer C
AU  - Pickett GE
AU  - Andersson T
AU  - Söderman M
AU  - Marotta TR
AU  - Cuellar-Saenz H
AU  - Thomas AJ
AU  - Patel AB
AU  - Mendes Pereira V
AU  - Adeeb N
AU  - Flow diversion Multinational Observational cohort Device comparsion (FlowMOD) Investigators
PY  - 2024
JO  - Clinical neuroradiology
DO  - 10.1007/s00062-024-01435-x
UR  - https://doi.org/10.1007/s00062-024-01435-x
ER  - 

APA

AA, D., HA, S., B, M., NM, C., CJ, G., RW, R., J, J., V, T., Z, H., N, L., SV, L., J, S., JD, R., MR, H., AH, S., EI, L., CJ, S., L, R., C, C., H, S., AL, K., MA, M., SI, T., P, J., P, T., F, S., MKS, H., A, N., D, V., P, H., DA, D., AS, P., M, P., JC, P., G, L., G, B., M, T., M, M., F, B., S, D., V, G., RE, A. G., JC, V., P, B., MH, S., C, S., GE, P., T, A., M, S., TR, M., H, C., AJ, T., AB, P., V, M. P., N, A., & Investigators, F. D. M. O. C. D. C. (. (2024). Comparative Efficacy of Flow Diverter Devices in the Treatment of Carotid Sidewall Intracranial Aneurysms: a Retrospective, Multicenter Study.. Clinical neuroradiology. https://doi.org/10.1007/s00062-024-01435-x

Source records