A pair of inverse ratiometric sensing paradigms based on stimulus response of AIE@ZIFs via solvent-assisted aggregation-induced emission modulation and substituent-dependent ligand emission regulation for dynamic monitoring of PFAS-induced ATP changes in cardiomyocytes.
- DOI
- 10.1007/s00604-026-08433-5
- Published
- 2026 Oct 1
- Container
- Mikrochimica acta
- Publisher
- Not recorded
- Open access
- unknown
Credibility signals
limited evidence Score 43/100 under policy 1.0.0. This is a metadata assessment, not a judgment of the paper's conclusions.
Show all credibility signals
- cautionDOI registered: No matching Crossref record was present in this response.
- cautionDOI resolves: No matching Crossref record was present in this response.
- not scoredDirectory of Open Access Journals: No matching DOAJ record was present in this response. No allow-list match; this is not evidence of low credibility.
- not scoredMEDLINE indexed: Not checked or no result supplied; no credibility inference made.
- not scoredOpenAlex core source: Not checked or no result supplied; no credibility inference made.
- not scoredKnown publisher allow-list: Not checked or no result supplied; no credibility inference made.
- not scoredROR affiliation: Not checked or no result supplied; no credibility inference made.
- not scoredRetraction Watch retraction: No retraction notice matched this DOI in the deployed snapshot. No matching event found; coverage may be incomplete.
- not scoredRetraction Watch expression of concern: No expression of concern notice matched this DOI in the deployed snapshot. No matching event found; coverage may be incomplete.
- not scoredRetraction Watch correction: No correction notice matched this DOI in the deployed snapshot. No matching event found; coverage may be incomplete.
- not scoredRetraction Watch reinstatement: No reinstatement notice matched this DOI in the deployed snapshot. No matching event found; coverage may be incomplete.
- not scoredOpen access status: Not checked or no result supplied; no credibility inference made.
- not scoredPublication license: Not checked or no result supplied; no credibility inference made.
- not scoredPublication version: A publication version was supplied but is not scored.
- cautionMetadata completeness: 5 of 6 scored descriptive metadata groups are present; missing fields increase uncertainty.
Cite this work
BibTeX
@article{allodium:10.1007/s00604-026-08433-5,
title = {A pair of inverse ratiometric sensing paradigms based on stimulus response of AIE@ZIFs via solvent-assisted aggregation-induced emission modulation and substituent-dependent ligand emission regulation for dynamic monitoring of PFAS-induced ATP changes in cardiomyocytes.},
author = {Min Y and Ge Z and Yu C and Zhang S and Xue C and Zhang Y and Zhou T and Zhai W and Deng J},
year = {2026},
journal = {Mikrochimica acta},
doi = {10.1007/s00604-026-08433-5},
url = {https://doi.org/10.1007/s00604-026-08433-5}
}RIS
TY - JOUR TI - A pair of inverse ratiometric sensing paradigms based on stimulus response of AIE@ZIFs via solvent-assisted aggregation-induced emission modulation and substituent-dependent ligand emission regulation for dynamic monitoring of PFAS-induced ATP changes in cardiomyocytes. AU - Min Y AU - Ge Z AU - Yu C AU - Zhang S AU - Xue C AU - Zhang Y AU - Zhou T AU - Zhai W AU - Deng J PY - 2026 JO - Mikrochimica acta DO - 10.1007/s00604-026-08433-5 UR - https://doi.org/10.1007/s00604-026-08433-5 ER -
APA
Y, M., Z, G., C, Y., S, Z., C, X., Y, Z., T, Z., W, Z., & J, D. (2026). A pair of inverse ratiometric sensing paradigms based on stimulus response of AIE@ZIFs via solvent-assisted aggregation-induced emission modulation and substituent-dependent ligand emission regulation for dynamic monitoring of PFAS-induced ATP changes in cardiomyocytes.. Mikrochimica acta. https://doi.org/10.1007/s00604-026-08433-5
Source records
- pubmed · retrieved 2026-11-10T16:51:38.645Z