Analytical model for managing hypotony after implantation surgery of a glaucoma drainage device.
- DOI
- 10.1007/s10237-021-01494-w
- Published
- 2021 Dec
- Container
- Biomechanics and modeling in mechanobiology
- Publisher
- Not recorded
- Open access
- yes
Credibility signals
limited evidence Score 45/100 under policy 1.0.0. This is a metadata assessment, not a judgment of the paper's conclusions.
Show all credibility signals
- cautionDOI registered: No matching Crossref record was present in this response.
- cautionDOI resolves: No matching Crossref record was present in this response.
- not scoredDirectory of Open Access Journals: No matching DOAJ record was present in this response. No allow-list match; this is not evidence of low credibility.
- not scoredMEDLINE indexed: Not checked or no result supplied; no credibility inference made.
- not scoredOpenAlex core source: Not checked or no result supplied; no credibility inference made.
- not scoredKnown publisher allow-list: Not checked or no result supplied; no credibility inference made.
- not scoredROR affiliation: Not checked or no result supplied; no credibility inference made.
- not scoredRetraction Watch retraction: No retraction notice matched this DOI in the deployed snapshot. No matching event found; coverage may be incomplete.
- not scoredRetraction Watch expression of concern: No expression of concern notice matched this DOI in the deployed snapshot. No matching event found; coverage may be incomplete.
- not scoredRetraction Watch correction: No correction notice matched this DOI in the deployed snapshot. No matching event found; coverage may be incomplete.
- not scoredRetraction Watch reinstatement: No reinstatement notice matched this DOI in the deployed snapshot. No matching event found; coverage may be incomplete.
- supportingOpen access status: Normalized open-access status: open.
- not scoredPublication license: Not checked or no result supplied; no credibility inference made.
- not scoredPublication version: A publication version was supplied but is not scored.
- cautionMetadata completeness: 5 of 6 scored descriptive metadata groups are present; missing fields increase uncertainty.
Cite this work
BibTeX
@article{allodium:10.1007/s10237-021-01494-w,
title = {Analytical model for managing hypotony after implantation surgery of a glaucoma drainage device.},
author = {Agujetas R and Kudiesh B and Fernández-Vigo JI and García-Feijóo J and Montanero JM},
year = {2021},
journal = {Biomechanics and modeling in mechanobiology},
doi = {10.1007/s10237-021-01494-w},
url = {https://doi.org/10.1007/s10237-021-01494-w}
}RIS
TY - JOUR TI - Analytical model for managing hypotony after implantation surgery of a glaucoma drainage device. AU - Agujetas R AU - Kudiesh B AU - Fernández-Vigo JI AU - García-Feijóo J AU - Montanero JM PY - 2021 JO - Biomechanics and modeling in mechanobiology DO - 10.1007/s10237-021-01494-w UR - https://doi.org/10.1007/s10237-021-01494-w ER -
APA
R, A., B, K., JI, F., J, G., & JM, M. (2021). Analytical model for managing hypotony after implantation surgery of a glaucoma drainage device.. Biomechanics and modeling in mechanobiology. https://doi.org/10.1007/s10237-021-01494-w
Source records
- pubmed · retrieved 2026-09-26T13:46:26.891Z