Real-time magnetic resonance-guided radiofrequency ablation and lesion evaluation in an magnetic resonance-compatible isolated beating pig heart platform
- DOI
- 10.1016/j.hroo.2025.09.014
- Published
- 2025-12
- Container
- Heart Rhythm O2
- Publisher
- Elsevier BV
- Open access
- unknown
Credibility signals
uncertain Score 64/100 under policy 1.0.0. This is a metadata assessment, not a judgment of the paper's conclusions.
Show all credibility signals
- supportingDOI registered: A matching record was returned by Crossref.
- supportingDOI resolves: A matching record was returned by Crossref.
- not scoredDirectory of Open Access Journals: No matching DOAJ record was present in this response. No allow-list match; this is not evidence of low credibility.
- not scoredMEDLINE indexed: Not checked or no result supplied; no credibility inference made.
- not scoredOpenAlex core source: Not checked or no result supplied; no credibility inference made.
- not scoredKnown publisher allow-list: Not checked or no result supplied; no credibility inference made.
- not scoredROR affiliation: Not checked or no result supplied; no credibility inference made.
- not scoredRetraction Watch retraction: No retraction notice matched this DOI in the deployed snapshot. No matching event found; coverage may be incomplete.
- not scoredRetraction Watch expression of concern: No expression of concern notice matched this DOI in the deployed snapshot. No matching event found; coverage may be incomplete.
- not scoredRetraction Watch correction: No correction notice matched this DOI in the deployed snapshot. No matching event found; coverage may be incomplete.
- not scoredRetraction Watch reinstatement: No reinstatement notice matched this DOI in the deployed snapshot. No matching event found; coverage may be incomplete.
- not scoredOpen access status: Not checked or no result supplied; no credibility inference made.
- not scoredPublication license: Not checked or no result supplied; no credibility inference made.
- not scoredPublication version: A publication version was supplied but is not scored.
- supportingMetadata completeness: All 6 scored descriptive metadata groups are present.
Cite this work
BibTeX
@article{allodium:10.1016/j.hroo.2025.09.014,
title = {Real-time magnetic resonance-guided radiofrequency ablation and lesion evaluation in an magnetic resonance-compatible isolated beating pig heart platform},
author = {Luuk H.G.A. Hopman and Eric M. Schrauben and Jules L. Nelissen and Pieter J. Reitzema and Machteld J. Boonstra and Bart L.M. Smeets and Renate W. Boekhoven and Daniel Sunnarborg and Jouke Smink and Hans W.M. Niessen and Cornelis P. Allaart and Aart J. Nederveen and Marco J.W. Götte},
year = {2025},
journal = {Heart Rhythm O2},
doi = {10.1016/j.hroo.2025.09.014},
url = {https://doi.org/10.1016/j.hroo.2025.09.014}
}RIS
TY - JOUR TI - Real-time magnetic resonance-guided radiofrequency ablation and lesion evaluation in an magnetic resonance-compatible isolated beating pig heart platform AU - Luuk H.G.A. Hopman AU - Eric M. Schrauben AU - Jules L. Nelissen AU - Pieter J. Reitzema AU - Machteld J. Boonstra AU - Bart L.M. Smeets AU - Renate W. Boekhoven AU - Daniel Sunnarborg AU - Jouke Smink AU - Hans W.M. Niessen AU - Cornelis P. Allaart AU - Aart J. Nederveen AU - Marco J.W. Götte PY - 2025 JO - Heart Rhythm O2 DO - 10.1016/j.hroo.2025.09.014 UR - https://doi.org/10.1016/j.hroo.2025.09.014 ER -
APA
Hopman, L. H., Schrauben, E. M., Nelissen, J. L., Reitzema, P. J., Boonstra, M. J., Smeets, B. L., Boekhoven, R. W., Sunnarborg, D., Smink, J., Niessen, H. W., Allaart, C. P., Nederveen, A. J., & Götte, M. J. (2025). Real-time magnetic resonance-guided radiofrequency ablation and lesion evaluation in an magnetic resonance-compatible isolated beating pig heart platform. Heart Rhythm O2. https://doi.org/10.1016/j.hroo.2025.09.014
Source records
- crossref · retrieved 2026-09-25T22:15:01.546Z