Infrarenal aortic balloon-expandable stent graft deployment using the sheath control technique in a patient with hemorrhagic shock secondary to an aortoenteric fistula
- DOI
- 10.1016/j.jvscit.2021.04.025
- Published
- 2021-09
- Container
- Journal of Vascular Surgery Cases, Innovations and Techniques
- Publisher
- Elsevier BV
- Open access
- unknown
Credibility signals
uncertain Score 64/100 under policy 1.0.0. This is a metadata assessment, not a judgment of the paper's conclusions.
Show all credibility signals
- supportingDOI registered: A matching record was returned by Crossref.
- supportingDOI resolves: A matching record was returned by Crossref.
- not scoredDirectory of Open Access Journals: No matching DOAJ record was present in this response. No allow-list match; this is not evidence of low credibility.
- not scoredMEDLINE indexed: Not checked or no result supplied; no credibility inference made.
- not scoredOpenAlex core source: Not checked or no result supplied; no credibility inference made.
- not scoredKnown publisher allow-list: Not checked or no result supplied; no credibility inference made.
- not scoredROR affiliation: Not checked or no result supplied; no credibility inference made.
- not scoredRetraction Watch retraction: No retraction notice matched this DOI in the deployed snapshot. No matching event found; coverage may be incomplete.
- not scoredRetraction Watch expression of concern: No expression of concern notice matched this DOI in the deployed snapshot. No matching event found; coverage may be incomplete.
- not scoredRetraction Watch correction: No correction notice matched this DOI in the deployed snapshot. No matching event found; coverage may be incomplete.
- not scoredRetraction Watch reinstatement: No reinstatement notice matched this DOI in the deployed snapshot. No matching event found; coverage may be incomplete.
- not scoredOpen access status: Not checked or no result supplied; no credibility inference made.
- not scoredPublication license: Not checked or no result supplied; no credibility inference made.
- not scoredPublication version: A publication version was supplied but is not scored.
- supportingMetadata completeness: All 6 scored descriptive metadata groups are present.
Cite this work
BibTeX
@article{allodium:10.1016/j.jvscit.2021.04.025,
title = {Infrarenal aortic balloon-expandable stent graft deployment using the sheath control technique in a patient with hemorrhagic shock secondary to an aortoenteric fistula},
author = {Cameron J. Overfield and Benjamin J. McCormick and Young Erben and Hollie Saunders and Johnathan M. Sheele and John E. Moss and Beau Toskich},
year = {2021},
journal = {Journal of Vascular Surgery Cases, Innovations and Techniques},
doi = {10.1016/j.jvscit.2021.04.025},
url = {https://doi.org/10.1016/j.jvscit.2021.04.025}
}RIS
TY - JOUR TI - Infrarenal aortic balloon-expandable stent graft deployment using the sheath control technique in a patient with hemorrhagic shock secondary to an aortoenteric fistula AU - Cameron J. Overfield AU - Benjamin J. McCormick AU - Young Erben AU - Hollie Saunders AU - Johnathan M. Sheele AU - John E. Moss AU - Beau Toskich PY - 2021 JO - Journal of Vascular Surgery Cases, Innovations and Techniques DO - 10.1016/j.jvscit.2021.04.025 UR - https://doi.org/10.1016/j.jvscit.2021.04.025 ER -
APA
Overfield, C. J., McCormick, B. J., Erben, Y., Saunders, H., Sheele, J. M., Moss, J. E., & Toskich, B. (2021). Infrarenal aortic balloon-expandable stent graft deployment using the sheath control technique in a patient with hemorrhagic shock secondary to an aortoenteric fistula. Journal of Vascular Surgery Cases, Innovations and Techniques. https://doi.org/10.1016/j.jvscit.2021.04.025
Source records
- crossref · retrieved 2026-09-26T03:31:57.566Z