Continuous Delivery of Hyperpolarized Xenon-129 Gas Using a “Stopped-Flow” Clinical-Scale Cryogen-Free Hyperpolarizer
- DOI
- 10.1021/acs.analchem.4c05372
- Published
- 2025-02-04
- Container
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Open access
- unknown
Credibility signals
uncertain Score 64/100 under policy 1.0.0. This is a metadata assessment, not a judgment of the paper's conclusions.
Show all credibility signals
- supportingDOI registered: A matching record was returned by Crossref.
- supportingDOI resolves: A matching record was returned by Crossref.
- not scoredDirectory of Open Access Journals: No matching DOAJ record was present in this response. No allow-list match; this is not evidence of low credibility.
- not scoredMEDLINE indexed: Not checked or no result supplied; no credibility inference made.
- not scoredOpenAlex core source: Not checked or no result supplied; no credibility inference made.
- not scoredKnown publisher allow-list: Not checked or no result supplied; no credibility inference made.
- not scoredROR affiliation: Not checked or no result supplied; no credibility inference made.
- not scoredRetraction Watch retraction: No retraction notice matched this DOI in the deployed snapshot. No matching event found; coverage may be incomplete.
- not scoredRetraction Watch expression of concern: No expression of concern notice matched this DOI in the deployed snapshot. No matching event found; coverage may be incomplete.
- not scoredRetraction Watch correction: No correction notice matched this DOI in the deployed snapshot. No matching event found; coverage may be incomplete.
- not scoredRetraction Watch reinstatement: No reinstatement notice matched this DOI in the deployed snapshot. No matching event found; coverage may be incomplete.
- not scoredOpen access status: Not checked or no result supplied; no credibility inference made.
- not scoredPublication license: Not checked or no result supplied; no credibility inference made.
- not scoredPublication version: A publication version was supplied but is not scored.
- supportingMetadata completeness: All 6 scored descriptive metadata groups are present.
Cite this work
BibTeX
@article{allodium:10.1021/acs.analchem.4c05372,
title = {Continuous Delivery of Hyperpolarized Xenon-129 Gas Using a “Stopped-Flow” Clinical-Scale Cryogen-Free Hyperpolarizer},
author = {Md Raduanul H. Chowdhury and Clementinah Oladun and Firoz Ahmed and Nuwandi M. Ariyasingha and Abubakar Abdurraheem and Faisal Asif and Joseph Gyesi and Panayiotis Nikolaou and Michael J. Barlow and Anton Shcherbakov and Nathan A. Rudman and Ivan J. Dmochowski and Boyd M. Goodson and Eduard Y. Chekmenev},
year = {2025},
journal = {Analytical Chemistry},
doi = {10.1021/acs.analchem.4c05372},
url = {https://doi.org/10.1021/acs.analchem.4c05372}
}RIS
TY - JOUR TI - Continuous Delivery of Hyperpolarized Xenon-129 Gas Using a “Stopped-Flow” Clinical-Scale Cryogen-Free Hyperpolarizer AU - Md Raduanul H. Chowdhury AU - Clementinah Oladun AU - Firoz Ahmed AU - Nuwandi M. Ariyasingha AU - Abubakar Abdurraheem AU - Faisal Asif AU - Joseph Gyesi AU - Panayiotis Nikolaou AU - Michael J. Barlow AU - Anton Shcherbakov AU - Nathan A. Rudman AU - Ivan J. Dmochowski AU - Boyd M. Goodson AU - Eduard Y. Chekmenev PY - 2025 JO - Analytical Chemistry DO - 10.1021/acs.analchem.4c05372 UR - https://doi.org/10.1021/acs.analchem.4c05372 ER -
APA
Chowdhury, M. R. H., Oladun, C., Ahmed, F., Ariyasingha, N. M., Abdurraheem, A., Asif, F., Gyesi, J., Nikolaou, P., Barlow, M. J., Shcherbakov, A., Rudman, N. A., Dmochowski, I. J., Goodson, B. M., & Chekmenev, E. Y. (2025). Continuous Delivery of Hyperpolarized Xenon-129 Gas Using a “Stopped-Flow” Clinical-Scale Cryogen-Free Hyperpolarizer. Analytical Chemistry. https://doi.org/10.1021/acs.analchem.4c05372
Source records
- crossref · retrieved 2026-09-26T00:15:30.974Z