Strain Analysis in Cementless Hip Femoral Prosthesis using the Finite Element Method - Influence of the Variability of the Angular Positioning of the Implant.
- DOI
- 10.1055/s-0041-1735141
- Published
- 2021-12-13
- Container
- Rev Bras Ortop (Sao Paulo)
- Publisher
- Not recorded
- Open access
- yes
Credibility signals
limited evidence Score 45/100 under policy 1.0.0. This is a metadata assessment, not a judgment of the paper's conclusions.
Show all credibility signals
- cautionDOI registered: No matching Crossref record was present in this response.
- cautionDOI resolves: No matching Crossref record was present in this response.
- not scoredDirectory of Open Access Journals: No matching DOAJ record was present in this response. No allow-list match; this is not evidence of low credibility.
- not scoredMEDLINE indexed: Not checked or no result supplied; no credibility inference made.
- not scoredOpenAlex core source: Not checked or no result supplied; no credibility inference made.
- not scoredKnown publisher allow-list: Not checked or no result supplied; no credibility inference made.
- not scoredROR affiliation: Not checked or no result supplied; no credibility inference made.
- not scoredRetraction Watch retraction: No retraction notice matched this DOI in the deployed snapshot. No matching event found; coverage may be incomplete.
- not scoredRetraction Watch expression of concern: No expression of concern notice matched this DOI in the deployed snapshot. No matching event found; coverage may be incomplete.
- not scoredRetraction Watch correction: No correction notice matched this DOI in the deployed snapshot. No matching event found; coverage may be incomplete.
- not scoredRetraction Watch reinstatement: No reinstatement notice matched this DOI in the deployed snapshot. No matching event found; coverage may be incomplete.
- supportingOpen access status: Normalized open-access status: open.
- not scoredPublication license: Not checked or no result supplied; no credibility inference made.
- not scoredPublication version: A publication version was supplied but is not scored.
- cautionMetadata completeness: 5 of 6 scored descriptive metadata groups are present; missing fields increase uncertainty.
Cite this work
BibTeX
@article{allodium:10.1055/s-0041-1735141,
title = {Strain Analysis in Cementless Hip Femoral Prosthesis using the Finite Element Method - Influence of the Variability of the Angular Positioning of the Implant.},
author = {Degasperi FA and Scatigna BF and Falótico GG and Romero V and Basile R and Takata ET.},
year = {2022},
journal = {Rev Bras Ortop (Sao Paulo)},
doi = {10.1055/s-0041-1735141},
url = {https://doi.org/10.1055/s-0041-1735141}
}RIS
TY - JOUR TI - Strain Analysis in Cementless Hip Femoral Prosthesis using the Finite Element Method - Influence of the Variability of the Angular Positioning of the Implant. AU - Degasperi FA AU - Scatigna BF AU - Falótico GG AU - Romero V AU - Basile R AU - Takata ET. PY - 2022 JO - Rev Bras Ortop (Sao Paulo) DO - 10.1055/s-0041-1735141 UR - https://doi.org/10.1055/s-0041-1735141 ER -
APA
FA, D., BF, S., GG, F., V, R., R, B., & ET., T. (2022). Strain Analysis in Cementless Hip Femoral Prosthesis using the Finite Element Method - Influence of the Variability of the Angular Positioning of the Implant.. Rev Bras Ortop (Sao Paulo). https://doi.org/10.1055/s-0041-1735141
Source records
- europe-pmc · retrieved 2026-09-27T09:55:36.847Z