Improved signal to noise ratio and sensitivity of an infrared imaging video bolometer on large helical device by using an infrared periscope.
- DOI
- 10.1063/1.4891317
- Published
- 2014 Jul
- Container
- The Review of scientific instruments
- Publisher
- Not recorded
- Open access
- unknown
Credibility signals
limited evidence Score 43/100 under policy 1.0.0. This is a metadata assessment, not a judgment of the paper's conclusions.
Show all credibility signals
- cautionDOI registered: No matching Crossref record was present in this response.
- cautionDOI resolves: No matching Crossref record was present in this response.
- not scoredDirectory of Open Access Journals: No matching DOAJ record was present in this response. No allow-list match; this is not evidence of low credibility.
- not scoredMEDLINE indexed: Not checked or no result supplied; no credibility inference made.
- not scoredOpenAlex core source: Not checked or no result supplied; no credibility inference made.
- not scoredKnown publisher allow-list: Not checked or no result supplied; no credibility inference made.
- not scoredROR affiliation: Not checked or no result supplied; no credibility inference made.
- not scoredRetraction Watch retraction: No retraction notice matched this DOI in the deployed snapshot. No matching event found; coverage may be incomplete.
- not scoredRetraction Watch expression of concern: No expression of concern notice matched this DOI in the deployed snapshot. No matching event found; coverage may be incomplete.
- not scoredRetraction Watch correction: No correction notice matched this DOI in the deployed snapshot. No matching event found; coverage may be incomplete.
- not scoredRetraction Watch reinstatement: No reinstatement notice matched this DOI in the deployed snapshot. No matching event found; coverage may be incomplete.
- not scoredOpen access status: Not checked or no result supplied; no credibility inference made.
- not scoredPublication license: Not checked or no result supplied; no credibility inference made.
- not scoredPublication version: A publication version was supplied but is not scored.
- cautionMetadata completeness: 5 of 6 scored descriptive metadata groups are present; missing fields increase uncertainty.
Cite this work
BibTeX
@article{allodium:10.1063/1.4891317,
title = {Improved signal to noise ratio and sensitivity of an infrared imaging video bolometer on large helical device by using an infrared periscope.},
author = {Pandya SN and Peterson BJ and Mukai K and Sano R and Enokuchi A and Takeyama N},
year = {2014},
journal = {The Review of scientific instruments},
doi = {10.1063/1.4891317},
url = {https://doi.org/10.1063/1.4891317}
}RIS
TY - JOUR TI - Improved signal to noise ratio and sensitivity of an infrared imaging video bolometer on large helical device by using an infrared periscope. AU - Pandya SN AU - Peterson BJ AU - Mukai K AU - Sano R AU - Enokuchi A AU - Takeyama N PY - 2014 JO - The Review of scientific instruments DO - 10.1063/1.4891317 UR - https://doi.org/10.1063/1.4891317 ER -
APA
SN, P., BJ, P., K, M., R, S., A, E., & N, T. (2014). Improved signal to noise ratio and sensitivity of an infrared imaging video bolometer on large helical device by using an infrared periscope.. The Review of scientific instruments. https://doi.org/10.1063/1.4891317
Source records
- pubmed · retrieved 2026-09-27T15:01:37.332Z