Magnetic Steering of Robotically Inserted Lateral-wall Cochlear-implant Electrode Arrays Reduces Forces on the Basilar Membrane In Vitro.
- DOI
- 10.1097/mao.0000000000003129
- Published
- 2021 Aug 1
- Container
- Otology & neurotology : official publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology
- Publisher
- Not recorded
- Open access
- yes
Credibility signals
limited evidence Score 45/100 under policy 1.0.0. This is a metadata assessment, not a judgment of the paper's conclusions.
Show all credibility signals
- cautionDOI registered: No matching Crossref record was present in this response.
- cautionDOI resolves: No matching Crossref record was present in this response.
- not scoredDirectory of Open Access Journals: No matching DOAJ record was present in this response. No allow-list match; this is not evidence of low credibility.
- not scoredMEDLINE indexed: Not checked or no result supplied; no credibility inference made.
- not scoredOpenAlex core source: Not checked or no result supplied; no credibility inference made.
- not scoredKnown publisher allow-list: Not checked or no result supplied; no credibility inference made.
- not scoredROR affiliation: Not checked or no result supplied; no credibility inference made.
- not scoredRetraction Watch retraction: No retraction notice matched this DOI in the deployed snapshot. No matching event found; coverage may be incomplete.
- not scoredRetraction Watch expression of concern: No expression of concern notice matched this DOI in the deployed snapshot. No matching event found; coverage may be incomplete.
- not scoredRetraction Watch correction: No correction notice matched this DOI in the deployed snapshot. No matching event found; coverage may be incomplete.
- not scoredRetraction Watch reinstatement: No reinstatement notice matched this DOI in the deployed snapshot. No matching event found; coverage may be incomplete.
- supportingOpen access status: Normalized open-access status: open.
- not scoredPublication license: Not checked or no result supplied; no credibility inference made.
- not scoredPublication version: A publication version was supplied but is not scored.
- cautionMetadata completeness: 5 of 6 scored descriptive metadata groups are present; missing fields increase uncertainty.
Cite this work
BibTeX
@article{allodium:10.1097/mao.0000000000003129,
title = {Magnetic Steering of Robotically Inserted Lateral-wall Cochlear-implant Electrode Arrays Reduces Forces on the Basilar Membrane In Vitro.},
author = {Hendricks CM and Cavilla MS and Usevitch DE and Bruns TL and Riojas KE and Leon L and Webster RJ 3rd and Warren FM and Abbott JJ},
year = {2021},
journal = {Otology \& neurotology : official publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology},
doi = {10.1097/mao.0000000000003129},
url = {https://doi.org/10.1097/mao.0000000000003129}
}RIS
TY - JOUR TI - Magnetic Steering of Robotically Inserted Lateral-wall Cochlear-implant Electrode Arrays Reduces Forces on the Basilar Membrane In Vitro. AU - Hendricks CM AU - Cavilla MS AU - Usevitch DE AU - Bruns TL AU - Riojas KE AU - Leon L AU - Webster RJ 3rd AU - Warren FM AU - Abbott JJ PY - 2021 JO - Otology & neurotology : official publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology DO - 10.1097/mao.0000000000003129 UR - https://doi.org/10.1097/mao.0000000000003129 ER -
APA
CM, H., MS, C., DE, U., TL, B., KE, R., L, L., 3rd, W. R., FM, W., & JJ, A. (2021). Magnetic Steering of Robotically Inserted Lateral-wall Cochlear-implant Electrode Arrays Reduces Forces on the Basilar Membrane In Vitro.. Otology & neurotology : official publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology. https://doi.org/10.1097/mao.0000000000003129
Source records
- pubmed · retrieved 2026-09-27T06:23:57.213Z