Small fields output factors measurements and correction factors determination for several detectors for a CyberKnife® and linear accelerators equipped with microMLC and circular cones.
- DOI
- 10.1118/1.4811139
- Published
- 2013 Jul
- Container
- Medical physics
- Publisher
- Not recorded
- Open access
- unknown
Credibility signals
limited evidence Score 43/100 under policy 1.0.0. This is a metadata assessment, not a judgment of the paper's conclusions.
Show all credibility signals
- cautionDOI registered: No matching Crossref record was present in this response.
- cautionDOI resolves: No matching Crossref record was present in this response.
- not scoredDirectory of Open Access Journals: No matching DOAJ record was present in this response. No allow-list match; this is not evidence of low credibility.
- not scoredMEDLINE indexed: Not checked or no result supplied; no credibility inference made.
- not scoredOpenAlex core source: Not checked or no result supplied; no credibility inference made.
- not scoredKnown publisher allow-list: Not checked or no result supplied; no credibility inference made.
- not scoredROR affiliation: Not checked or no result supplied; no credibility inference made.
- not scoredRetraction Watch retraction: No retraction notice matched this DOI in the deployed snapshot. No matching event found; coverage may be incomplete.
- not scoredRetraction Watch expression of concern: No expression of concern notice matched this DOI in the deployed snapshot. No matching event found; coverage may be incomplete.
- not scoredRetraction Watch correction: No correction notice matched this DOI in the deployed snapshot. No matching event found; coverage may be incomplete.
- not scoredRetraction Watch reinstatement: No reinstatement notice matched this DOI in the deployed snapshot. No matching event found; coverage may be incomplete.
- not scoredOpen access status: Not checked or no result supplied; no credibility inference made.
- not scoredPublication license: Not checked or no result supplied; no credibility inference made.
- not scoredPublication version: A publication version was supplied but is not scored.
- cautionMetadata completeness: 5 of 6 scored descriptive metadata groups are present; missing fields increase uncertainty.
Cite this work
BibTeX
@article{allodium:10.1118/1.4811139,
title = {Small fields output factors measurements and correction factors determination for several detectors for a CyberKnife® and linear accelerators equipped with microMLC and circular cones.},
author = {Bassinet C and Huet C and Derreumaux S and Brunet G and Chéa M and Baumann M and Lacornerie T and Gaudaire-Josset S and Trompier F and Roch P and Boisserie G and Clairand I},
year = {2013},
journal = {Medical physics},
doi = {10.1118/1.4811139},
url = {https://doi.org/10.1118/1.4811139}
}RIS
TY - JOUR TI - Small fields output factors measurements and correction factors determination for several detectors for a CyberKnife® and linear accelerators equipped with microMLC and circular cones. AU - Bassinet C AU - Huet C AU - Derreumaux S AU - Brunet G AU - Chéa M AU - Baumann M AU - Lacornerie T AU - Gaudaire-Josset S AU - Trompier F AU - Roch P AU - Boisserie G AU - Clairand I PY - 2013 JO - Medical physics DO - 10.1118/1.4811139 UR - https://doi.org/10.1118/1.4811139 ER -
APA
C, B., C, H., S, D., G, B., M, C., M, B., T, L., S, G., F, T., P, R., G, B., & I, C. (2013). Small fields output factors measurements and correction factors determination for several detectors for a CyberKnife® and linear accelerators equipped with microMLC and circular cones.. Medical physics. https://doi.org/10.1118/1.4811139