Calibration Procedure for Attenuation Coefficient Measurements in Highly Opaque Media Using Infrared Focal Plane Array (IRFPA) Spectroscopy.
- DOI
- 10.1177/0003702817736320
- Published
- 2018 Feb
- Container
- Applied spectroscopy
- Publisher
- Not recorded
- Open access
- unknown
Credibility signals
limited evidence Score 43/100 under policy 1.0.0. This is a metadata assessment, not a judgment of the paper's conclusions.
Show all credibility signals
- cautionDOI registered: No matching Crossref record was present in this response.
- cautionDOI resolves: No matching Crossref record was present in this response.
- not scoredDirectory of Open Access Journals: No matching DOAJ record was present in this response. No allow-list match; this is not evidence of low credibility.
- not scoredMEDLINE indexed: Not checked or no result supplied; no credibility inference made.
- not scoredOpenAlex core source: Not checked or no result supplied; no credibility inference made.
- not scoredKnown publisher allow-list: Not checked or no result supplied; no credibility inference made.
- not scoredROR affiliation: Not checked or no result supplied; no credibility inference made.
- not scoredRetraction Watch retraction: No retraction notice matched this DOI in the deployed snapshot. No matching event found; coverage may be incomplete.
- not scoredRetraction Watch expression of concern: No expression of concern notice matched this DOI in the deployed snapshot. No matching event found; coverage may be incomplete.
- not scoredRetraction Watch correction: No correction notice matched this DOI in the deployed snapshot. No matching event found; coverage may be incomplete.
- not scoredRetraction Watch reinstatement: No reinstatement notice matched this DOI in the deployed snapshot. No matching event found; coverage may be incomplete.
- not scoredOpen access status: Not checked or no result supplied; no credibility inference made.
- not scoredPublication license: Not checked or no result supplied; no credibility inference made.
- not scoredPublication version: A publication version was supplied but is not scored.
- cautionMetadata completeness: 5 of 6 scored descriptive metadata groups are present; missing fields increase uncertainty.
Cite this work
BibTeX
@article{allodium:10.1177/0003702817736320,
title = {Calibration Procedure for Attenuation Coefficient Measurements in Highly Opaque Media Using Infrared Focal Plane Array (IRFPA) Spectroscopy.},
author = {Kirchner S and Narinsamy S and Sommier A and Romano M and Ryu M and Morikawa J and Leng J and Batsale JC and Pradère C},
year = {2018},
journal = {Applied spectroscopy},
doi = {10.1177/0003702817736320},
url = {https://doi.org/10.1177/0003702817736320}
}RIS
TY - JOUR TI - Calibration Procedure for Attenuation Coefficient Measurements in Highly Opaque Media Using Infrared Focal Plane Array (IRFPA) Spectroscopy. AU - Kirchner S AU - Narinsamy S AU - Sommier A AU - Romano M AU - Ryu M AU - Morikawa J AU - Leng J AU - Batsale JC AU - Pradère C PY - 2018 JO - Applied spectroscopy DO - 10.1177/0003702817736320 UR - https://doi.org/10.1177/0003702817736320 ER -
APA
S, K., S, N., A, S., M, R., M, R., J, M., J, L., JC, B., & C, P. (2018). Calibration Procedure for Attenuation Coefficient Measurements in Highly Opaque Media Using Infrared Focal Plane Array (IRFPA) Spectroscopy.. Applied spectroscopy. https://doi.org/10.1177/0003702817736320
Source records
- pubmed · retrieved 2026-09-27T10:02:58.296Z