T<sub>1</sub> mapping performance and measurement repeatability: results from the multi-national T<sub>1</sub> mapping standardization phantom program (T1MES).
- DOI
- 10.1186/s12968-020-00613-3
- Published
- 2020-05-07
- Container
- J Cardiovasc Magn Reson
- Publisher
- Not recorded
- Open access
- yes
Credibility signals
uncertain Score 53/100 under policy 1.0.0. This is a metadata assessment, not a judgment of the paper's conclusions.
Show all credibility signals
- cautionDOI registered: No matching Crossref record was present in this response.
- cautionDOI resolves: No matching Crossref record was present in this response.
- supportingDirectory of Open Access Journals: A matching record was returned by DOAJ.
- not scoredMEDLINE indexed: Not checked or no result supplied; no credibility inference made.
- not scoredOpenAlex core source: Not checked or no result supplied; no credibility inference made.
- not scoredKnown publisher allow-list: Not checked or no result supplied; no credibility inference made.
- not scoredROR affiliation: Not checked or no result supplied; no credibility inference made.
- not scoredRetraction Watch retraction: No retraction notice matched this DOI in the deployed snapshot. No matching event found; coverage may be incomplete.
- not scoredRetraction Watch expression of concern: No expression of concern notice matched this DOI in the deployed snapshot. No matching event found; coverage may be incomplete.
- not scoredRetraction Watch correction: No correction notice matched this DOI in the deployed snapshot. No matching event found; coverage may be incomplete.
- not scoredRetraction Watch reinstatement: No reinstatement notice matched this DOI in the deployed snapshot. No matching event found; coverage may be incomplete.
- supportingOpen access status: Normalized open-access status: open.
- not scoredPublication license: Not checked or no result supplied; no credibility inference made.
- not scoredPublication version: A publication version was supplied but is not scored.
- cautionMetadata completeness: 5 of 6 scored descriptive metadata groups are present; missing fields increase uncertainty.
Cite this work
BibTeX
@article{allodium:10.1186/s12968-020-00613-3,
title = {T\<sub\>1\</sub\> mapping performance and measurement repeatability: results from the multi-national T\<sub\>1\</sub\> mapping standardization phantom program (T1MES).},
author = {Captur G and Bhandari A and Brühl R and Ittermann B and Keenan KE and Yang Y and Eames RJ and Benedetti G and Torlasco C and Ricketts L and Boubertakh R and Fatih N and Greenwood JP and Paulis LEM and Lawton CB and Bucciarelli-Ducci C and Lamb HJ and Steeds R and Leung SW and Berry C and Valentin S and Flett A and de Lange C and DeCobelli F and Viallon M and Croisille P and Higgins DM and Greiser A and Pang W and Hamilton-Craig C and Strugnell WE and Dresselaers T and Barison A and Dawson D and Taylor AJ and Taylor AJ and Mongeon FP and Plein S and Messroghli D and Al-Mallah M and Grieve SM and Lombardi M and Jang J and Salerno M and Chaturvedi N and Kellman P and Bluemke DA and Nezafat R and Gatehouse P and Moon JC and T1MES Consortium.},
year = {2020},
journal = {J Cardiovasc Magn Reson},
doi = {10.1186/s12968-020-00613-3},
url = {https://doi.org/10.1186/s12968-020-00613-3}
}RIS
TY - JOUR TI - T<sub>1</sub> mapping performance and measurement repeatability: results from the multi-national T<sub>1</sub> mapping standardization phantom program (T1MES). AU - Captur G AU - Bhandari A AU - Brühl R AU - Ittermann B AU - Keenan KE AU - Yang Y AU - Eames RJ AU - Benedetti G AU - Torlasco C AU - Ricketts L AU - Boubertakh R AU - Fatih N AU - Greenwood JP AU - Paulis LEM AU - Lawton CB AU - Bucciarelli-Ducci C AU - Lamb HJ AU - Steeds R AU - Leung SW AU - Berry C AU - Valentin S AU - Flett A AU - de Lange C AU - DeCobelli F AU - Viallon M AU - Croisille P AU - Higgins DM AU - Greiser A AU - Pang W AU - Hamilton-Craig C AU - Strugnell WE AU - Dresselaers T AU - Barison A AU - Dawson D AU - Taylor AJ AU - Taylor AJ AU - Mongeon FP AU - Plein S AU - Messroghli D AU - Al-Mallah M AU - Grieve SM AU - Lombardi M AU - Jang J AU - Salerno M AU - Chaturvedi N AU - Kellman P AU - Bluemke DA AU - Nezafat R AU - Gatehouse P AU - Moon JC AU - T1MES Consortium. PY - 2020 JO - J Cardiovasc Magn Reson DO - 10.1186/s12968-020-00613-3 UR - https://doi.org/10.1186/s12968-020-00613-3 ER -
APA
G, C., A, B., R, B., B, I., KE, K., Y, Y., RJ, E., G, B., C, T., L, R., R, B., N, F., JP, G., LEM, P., CB, L., C, B., HJ, L., R, S., SW, L., C, B., S, V., A, F., C, D. L., F, D., M, V., P, C., DM, H., A, G., W, P., C, H., WE, S., T, D., A, B., D, D., AJ, T., AJ, T., FP, M., S, P., D, M., M, A., SM, G., M, L., J, J., M, S., N, C., P, K., DA, B., R, N., P, G., JC, M., & Consortium., T. (2020). T<sub>1</sub> mapping performance and measurement repeatability: results from the multi-national T<sub>1</sub> mapping standardization phantom program (T1MES).. J Cardiovasc Magn Reson. https://doi.org/10.1186/s12968-020-00613-3
Source records
- europe-pmc · retrieved 2026-09-25T11:37:35.046Z
- doaj · retrieved 2026-09-25T11:37:35.032Z
- hal · retrieved 2026-09-25T11:37:35.093Z