Biomechanical in vitro - stability testing on human specimens of a locking plate system against conventional screw fixation of a proximal first metatarsal lateral displacement osteotomy.
- DOI
- 10.2174/1874325001206010133
- Published
- 2012
- Container
- The open orthopaedics journal
- Publisher
- Not recorded
- Open access
- yes
Credibility signals
limited evidence Score 45/100 under policy 1.0.0. This is a metadata assessment, not a judgment of the paper's conclusions.
Show all credibility signals
- cautionDOI registered: No matching Crossref record was present in this response.
- cautionDOI resolves: No matching Crossref record was present in this response.
- not scoredDirectory of Open Access Journals: No matching DOAJ record was present in this response. No allow-list match; this is not evidence of low credibility.
- not scoredMEDLINE indexed: Not checked or no result supplied; no credibility inference made.
- not scoredOpenAlex core source: Not checked or no result supplied; no credibility inference made.
- not scoredKnown publisher allow-list: Not checked or no result supplied; no credibility inference made.
- not scoredROR affiliation: Not checked or no result supplied; no credibility inference made.
- not scoredRetraction Watch retraction: No retraction notice matched this DOI in the deployed snapshot. No matching event found; coverage may be incomplete.
- not scoredRetraction Watch expression of concern: No expression of concern notice matched this DOI in the deployed snapshot. No matching event found; coverage may be incomplete.
- not scoredRetraction Watch correction: No correction notice matched this DOI in the deployed snapshot. No matching event found; coverage may be incomplete.
- not scoredRetraction Watch reinstatement: No reinstatement notice matched this DOI in the deployed snapshot. No matching event found; coverage may be incomplete.
- supportingOpen access status: Normalized open-access status: open.
- not scoredPublication license: Not checked or no result supplied; no credibility inference made.
- not scoredPublication version: A publication version was supplied but is not scored.
- cautionMetadata completeness: 5 of 6 scored descriptive metadata groups are present; missing fields increase uncertainty.
Cite this work
BibTeX
@article{allodium:10.2174/1874325001206010133,
title = {Biomechanical in vitro - stability testing on human specimens of a locking plate system against conventional screw fixation of a proximal first metatarsal lateral displacement osteotomy.},
author = {Arnold H and Stukenborg-Colsman C and Hurschler C and Seehaus F and Bobrowitsch E and Waizy H},
year = {2012},
journal = {The open orthopaedics journal},
doi = {10.2174/1874325001206010133},
url = {https://doi.org/10.2174/1874325001206010133}
}RIS
TY - JOUR TI - Biomechanical in vitro - stability testing on human specimens of a locking plate system against conventional screw fixation of a proximal first metatarsal lateral displacement osteotomy. AU - Arnold H AU - Stukenborg-Colsman C AU - Hurschler C AU - Seehaus F AU - Bobrowitsch E AU - Waizy H PY - 2012 JO - The open orthopaedics journal DO - 10.2174/1874325001206010133 UR - https://doi.org/10.2174/1874325001206010133 ER -
APA
H, A., C, S., C, H., F, S., E, B., & H, W. (2012). Biomechanical in vitro - stability testing on human specimens of a locking plate system against conventional screw fixation of a proximal first metatarsal lateral displacement osteotomy.. The open orthopaedics journal. https://doi.org/10.2174/1874325001206010133
Source records
- pubmed · retrieved 2026-09-26T02:17:16.616Z